Emergency Lighting · Waterford

Emergency Lighting Testing & Certification in Waterford

ADS Group tests, certifies, designs and installs emergency lighting to I.S. 3217 across Waterford city and county. The standard requires a monthly functional test and an annual full-duration discharge test, normally three hours. In healthcare and production premises the escape strategy is not a simple exit, and the lighting has to support the strategy the building actually uses.

What matters for Waterford buildings

Horizontal evacuation needs the route to the next compartment lit

Where occupants move to an adjoining compartment rather than outside, the lit route is the one through the fire doors into that compartment, including the space they will wait in. A design that only lights the path to an external exit misses what the building is actually going to do.

Plant and production routes are not corridors

An escape route through a production area passes machinery, level changes and equipment that moves. Those points need lighting, and they are where a generic layout leaves gaps.

Historic premises need discreet fittings and more of them

The older city core has routes with stairs, turns and low headroom, each of which needs lighting, and interiors that cannot take surface trunking. Both are solvable, but not with a standard fitting layout.

What the visit includes

  • Annual full-duration discharge test, normally three hours, on every luminaire
  • Route to adjoining compartments lit where progressive horizontal evacuation is used
  • Changes of direction, stairs and level changes assessed for coverage
  • Monthly functional test regime set up, with a log your own staff can maintain
  • Failed batteries, lamps and fittings reported in writing with a quotation for remedial work
  • Certification to I.S. 3217 on completion

Full detail on the system types, the standards and the certification process is on the Emergency Lighting page, and everything else we cover in the county is on the Waterford page.

Frequently asked questions

Does emergency lighting differ in a healthcare building?
The standard is the same, but the strategy usually is not. Where occupants move to an adjoining compartment rather than outside, the lighting has to cover that route and the area they move into, not just the path to an external door.
Can the test be staged so the building is not fully on battery?
Yes. On larger premises the discharge test is run by area or by floor so the whole building is never on emergency supply at once.
Do you cover Dungarvan as well as the city?
Yes, along with Tramore, Lismore and the rest of the county.

Request a survey in Waterford

An engineer assesses the site, reviews the existing system and its documentation, and returns a written scope of works.

01 620 6758